Add to Cart
Xenon Weathering Chamber Automatic
Air Cooled Light Fastness Tester Color Fastness To Light
General specifications
Packaging Dimensions: (W x D x H) 1280×1150×2200mm
Power supply source: AC380V±10%, 50/60Hz (can be appointed)
Gross Weight: 400kg
Introduction
This machine designed to meet the requirements of ISO 105 B02 and AATCC Test Method 16 standards. It has a rotating specimen rack and provides precise control of critical test parameters including spectrum, irradiance, relative humidity, chamber temperature and black standard temperature.
Usage
To determine the resistance of the color of textiles to fade when exposed to artificial light (xenon arc) which is representative of natural daylight.
Testing standards
ISO 105-B02 Textiles -- Tests for color fastness -- Part B02: Color fastness to artificial light: Xenon arc fading lamp test
ISO 105-B04 Textiles -- Tests for color fastness -- Part B04: Color fastness to artificial weathering: Xenon arc fading lamp test
AATCC TM 16 – Option 3 Colorfastness to Light: Xenon-Arc
feature
1. Xenon lamp ventilation and cooling device: The box temperature ventilation and cooling system adopts Taiwan high temperature resistant turbo fan to cool down, and the cooling system inside the box cools down.
2. Light box temperature alarm device: It can monitor the temperature in the light box through the PT100 high-precision sensor, monitor the over-temperature alarm and cut off the power supply of the xenon lamp.
3. The blackboard thermometer adopts wired transmission technology, which effectively improves the control precision. (Using high temperature resistant isolation and shielded communication line)
4. Optical fiber transmission is used to measure the radiation intensity of the xenon lamp to avoid measurement errors caused by temperature. (optional accessory)
5. A BPT (black panel thermometer) or BST (black standard thermometer) is mounted on the sample holder.
6. Device: In order to record the working time of each test, the device is equipped with a timer on the operation panel, which can control the time of the device, and the device will automatically shut down after the timer ends.
7. Protection device: In order to make the xenon arc lamp work normally without damage, when the door is opened, the xenon lamp will automatically go out and the whole machine will stop working.
Technical parameters
Internal Dimension (W*D*H) | 600×600×800 | |
External Dimension (W*D*H) | 1220×1100×2100 | |
performance indicators | Chamber temperature | 10~95℃ |
Temperature accuracy | ±5℃ | |
Black panel temperature | 30~110℃ | |
Chamber humidity range | 15%RH~85%RH | |
Humidity accuracy | ±5%RH | |
Irradiance Range | 420nm | |
Irradiance strength | 0.55~1.3W/m2 | |
Irradiance accuracy | ±0.03W/m2/ | |
Xenon lamp power | 2500W air-cooled xenon arc lamp (recommend replacing lamps every 1200 hours) | |
Rack rotating speed | 5r/min | |
Test Positions | 10 pieces of 145x 45mm, 5 pieces of 145x 75mm | |
Exposure Area of each Test Position | ISO 65.25cm² (145 x 45) mm AATCC 108.75cm² (145 x 75) mm | |
operation control system | water spray system | The water spray time can be set in 999 minutes, and the spray stop time can be set in 999 minutes |
Accuracy range | Setting/indication accuracy: temperature 0.1℃, humidity 1%RH | |
Temperature and humidity sensor | Platinum resistance.PT100Ω/MV | |
Heating system | Fully independent system, nickel-chromium alloy electric heating heater | |
humidification system | External isolation, all stainless steel shallow surface evaporative humidifier | |
blackboard temperature | Bimetal Blackboard Thermometer | |
circulatory system | Temperature-resistant and low-noise air-conditioning motor. Multi-blade centrifugal fan | |
material | Internal chamber material | High-quality carbon steel plate, phosphating electrostatic spray treatment / stainless steel matte line hairline treatment |
External chamber material | SUS 304 # Stainless Steel, anti-rust | |
Sample holder material | SUS 304 # Stainless Steel, anti-rust | |
Standard accessories | radiation-proof glass windows-1 set, Xenon lamp-1 PC | |
safety protection | Leakage, short circuit, over temperature, water shortage, motor overheating, overcurrent protection | |
Power supply | AC380V±10% 50±0.5Hz,13W |
customer letter
Why choose us?
1.Design & Production : Solution Consultation for each order
Recommend the most cost -performance machine
Research & Develop the suitable one for Special- designed Model.
2.Shipping & Delivery: One-Stop Service
Production- Deliver to your door - Installation & Training- Technical Support
3.Warranty
1 year warranty with lifetime technology support
4.After-Sale Service
React within 2 Hours
Video inspection & on-site service combined